Take the mystery out of pump terminology. Wastecorp uses the following industry standard terms in our pump engineering specification documents:
Discharge Head: This is the vertical distance that you are able to pump liquid. For example, if your pump is rated for a maximum head of 18 feet, this does not mean that you are restricted to 18 feet of pipe. You can use 300 feet, so long as the final discharge point is not higher than 18 feet above the liquid being pumped.
Suction Lift: This is the vertical distance that the pump can be above the liquid source. Typically, atmospheric pressure limits vertical suction lift of pumps to 25 feet at sea level. This does not mean that you are limited to 25 feet of pipe. You could use upwards of 300 feet of suction pipe, so long as the liquid source is not lower than 25 feet below the pump center line.
Total Head: Sum of discharge head, suction lift, and friction loss.
Total Dynamic Head: Used when calculating dynamic discharge head plus dynamic suction lift or minus dynamic suction head into one computation.
Friction Head: Pressure expressed in Lbs., required to overcome the resistance to the flow in the pipe system.
Suction Lift: Used when the liquid source is located below the center line of the pump
Suction Head: Used when the liquid source is located above the center line of the pump. This may also be referred to as "flooded suction."
Static Suction Lift: Used to describe the distance from the pump center line down to the free level of the liquid source below the pump.
Static Suction Head: Used to describe the distance from the center line of the pump up to the free level of the liquid source above the pump.
Static Discharge Head: Used to describe the maximum vertical distance from the pump center line to the point of free discharge.
Dynamic Suction Lift: Used when calculating the static suction lift, friction head loss and velocity head into one computation.
Dynamic Suction Head: Used when calculating the static suction head minus friction head and velocity head.
Dynamic Discharge Head: Used when calculating static discharge head, friction head plus velocity head into one computation.
Flooded Suction: Liquid flows to pump inlet from an elevated source by means of gravity
Suction Lift at Various Elevations
Altitude (ft) | Suction Lift (ft) |
Sea Level | 25.0 |
2,000 | 22.0 |
4,000 | 19.5 |
6,000 | 17.3 |
8,000 | 15.5 |
10,000 | 14.3 |
The Altitude Factor (Facilities at higher elevations)
Since air is thinner and heat is not dissipated easily at higher altitudes, standard motors are designed to operate below 3,300 ft. Most motors must be derated at higher altitudes. The chart below provides typical horsepower derating factor. A 3 HP motor operating at 6000 feet for example would be derated to 2.82 HP, assuming a 40 degree ambient temperature rating.
Example : 3HP x 0.94 = 2.82
Altitude | Derating Factor |
3,300-5,000 | 0.97 |
5,001-6,600 | 0.94 |
6,601-8,300 | 0.90 |
8,301-9,900 | 0.86 |
9,901-11,500 | 0.82 |